Measuring up · Heatable area

You do not heat a room, you heat the floor left over once the fixed furniture is out of it. Three measurements and this page gives you the number a quote is built from.

3
Measurements needed
10%
Perimeter and spacing allowance
80%
Below this, a rethink is worth it
The method

Top-down floor plan of an empty room01

Measure the room

Length times width, in feet, for the whole room. This is your gross floor area and everything else is taken off it.

Bathroom interior with fixed furniture02

Subtract what is fixed

Anything that will never move comes out: kitchen units and islands, bathroom suites, built-in storage, storage radiators. Measure each one and enter it below. Heating a floor nobody stands on is the most common way to overspend.

Clean modern floor ready for underfloor heating03

Take off the perimeter

A further 10% comes off for the 50–100 mm gap around the edge of the room and the spacing needed so matting does not overlap itself. What is left is your heatable area.

The calculator

Enter the room, then add a row for each fixed obstruction. The perimeter allowance is applied for you.

The room
Fixed obstructions

One row per item that will never move. Leave the single empty row if there are none.

Enter the room width and length to continue.

Installation economics

Adjust the project parameters below to understand how your electric hamam installation is technically and commercially structured.

1

Heating system brand

2

Room dimensions

sq ft
×
%

Recommended 80% coverage for even heat distribution.

3

Heating mats required

Enter room dimensions above to see mat recommendations.

4

Thermostat control

Standard Thermostat

Included free

Modular Thermostat

+ ₹2,500

Wi-Fi Smart Thermostat

+ ₹5,500

Summary

Cost breakdown

Heating Mats

No mats selected

Total Coverage

Enter room dimensions

Mat Cost

Thermostat

Standard Thermostat

Included

Mat + thermostat cost

0

Then which system

Electric underfloor heating cables close-upElectric

Electric underfloor heating

When buying a mat system you reduce the heatable area by 10% to allow for a 50 mm to 100 mm perimeter around the room, plus spacing so the matting does not overlap itself.

For awkwardly shaped rooms such as bathrooms, a loose cable is the better answer. It maximises the heated area, installs more easily around fittings, and gives more even heat.

The heating element cannot be shortened on site, doing so invalidates the warranty, so ordering the correct size is essential.

See electric systems
Water underfloor heating pipes laid in a serpentine patternWater / wet

Water (wet) underfloor heating

Wet systems circulate warm water through pipework connected to a manifold, so the heatable area also has to account for pipe centres and the manifold's own footprint in the room.

Because pipework sets into screed or a low-profile board, water systems suit new builds and larger renovations, where floor build-up height can be planned in from the start.

Pipe runs are continuous per zone and cannot be shortened on site, so accurate measurements decide the manifold and pipe lengths you order.

Talk to us about water systems
Next step

Bring your figure to the free site visit. We measure it properly, check the floor build-up and the supply, and turn it into a written quote.